78 www.behnke-online.de
GB
Instructions SIP intercoms series 20-0001BS, 20-0014BS, 20-0016BS
Commissioning and configuration
Actuation time for direct call buttons Default: 0
04 0 # minimally
1 # 1 second
: :
5 # 5 seconds
Here you can set how long a physical direct call button must be pressed before the keystroke is
recognised as valid and the button's configured call number is called.
Increasing the actuation time can reduce false triggering. In most cases however, a minimum actua-
tion time is the correct setting.
This setting does not apply to direct call buttons that are connected via an expansion module.
Their actuation time is fixed and cannot be changed.
Maximum connection time Default: 3
05 0 # unlimited
1 # 1 minute
: :
9 # 9 minutes
The maximum duration for a connection is set here.
For an outgoing call, the connection duration starts after the remote station is answered.
For an incoming call, it starts after the call has been accepted.
After the maximum connection time has elapsed, the connection is automatically disconnected.
Volume Default: *80
06 0 # Level 0 (0%)
1 # Level 1 (11%)
2 # Level 2 (22%)
: :
9 # Level 9 (99%)
*0 # 0%
: :
*100 # 100%
The volume of the speaker output can be set in levels from 0 (=quiet) to 9 (=loud).
Alternatively, it is possible to specify the desired volume in percent (*0 to *100).