52 Linea 2K and 4K Monochrome Line Scan Camera User's Manual
03-032-20206-00 Teledyne DALSA
Flat Field Control Feature Description
The following table describes these parameters along with their view attribute and minimum camera
firmware version required. Additionally the firmware column will indicate which parameter is a
member of the DALSA Features Naming Convention (DFNC), verses the GenICam Standard Features
Naming Convention (SFNC not shown).
The Device Version number represents the camera software functional group, not a firmware revision
number.
FPN and flat field coefficients
disabled.
FPN and flat field coefficients
enabled.
Reset all FPN to 0 and all flat field
coefficients to 1.
flatfieldCorrectionAlgorithm
Selection between two different
flat field algorithms.
Direct calculation of coefficients
based on average line values and
target. First each color is flat
fielded to its peak value and then
the color gains are used to achieve
the target.
A low pass filter is first applied to
the average line values before
calculating the coefficients. Use
this algorithm if the calibration
target is not uniformly white or it
is not possible to defocus the
image. Because of the low pass
filter this algorithm is not able to
correct pixel-to-pixel variations
and so it is preferable to use the
―Basic‖ algorithm.
flatfieldCalibrationTarget
Set a value between 0 and 255 to
which the flat field algorithm will
taget the image to.
Calibration Sample Size
Lines_2048
Lines_4096
flatfieldCalibrationSampleSize
Lines_2048
Lines_4096
Sets the number of lines to be
averaged during a flat field
calibration
flatfieldCalibrationROIOffsetX
Set the starting point of a region
of interest where a flat field
calibration will be performed
flatfieldCalibrationROIWidth
Sets the width of the region on
interest where a flat field
calibration will be performed