User Manual E3
59300623 Rev.001
5.4.2018 11(20)
Alarms
The E3 alarms displayed in local user interface and PC / Android viewer are
described in the table below.
The alarm texts are displayed in separate rows in the local user interface. When
the display is sleeping, slowly blinking dot “.” means no alarms and rapidly
blinking “E” means at least one alarm. See also “Local user interface” chapter.
Description & suggested corrective action
Internal error
E3 has an internal error. If resetting the unit doesn't help,
contact Teleste support.
E.PLu
Unknown module
E3 is not able to recognise RIS module or diplex filter type,
or diplex filter frequencies do not match. If software is up to
date and removing and reinstalling the plug-in modules
doesn't help, contact Teleste support.
E.PSu
Power supply
failure
Internal voltages are not OK. If the AC supply voltage is
within specification and resetting the unit doesn't help,
Remote AC voltage is above 65 V
RMS
.
Remote AC voltage is below 27 V
RMS
.
E.TMP
Internal temperature is above 85 °C.
Internal temperature is below -20 °C.
Table 3. E3 alarms