User Manual E3
59300623 Rev.001
5.4.2018 12(20)
Local user interface
E3 has a local user interface consisting of a 4*7-segment display and 3 buttons.
This local UI can be used for E3 configuration in cases where E61 RIS module
is not installed or the use of a PC, tablet or smartphone equipped with CATVisor
Commander is not desired.
Using the local user interface
During power-up "Teleste E3R/L X.Y" text (where X.Y indicates the installed
software version, R indicates remote powering and L local powering) scrolls
through the display. Pressing the “Enter” button (right button with ■ symbol)
wakes up the display and activates the first menu item. If there is no button
activity during ~3 minutes, the display will go to sleep mode. When in sleep
mode, a slowly blinking dot “.” in the display indicates no alarms and rapidly
blinking “E” indicates alarms.
The menu structure is described in Figure 5. The “Up” (left button with ▲
symbol) and “Down” (middle button with ▼ symbol) buttons browse through the
menu items, The “Enter” button selects the item for modification / reading, “Up” /
“Down” changes the value of the selected item and “Enter” returns to the menu.
Possible alarms are displayed in separate rows in the beginning of the menu.
For additional information about alarms, see the “Alarms” chapter.
PIN code
A PIN code can be used to prevent unauthorised local access. The PIN code is
disabled (0000) as factory default. It can be changed via the local user interface
or via PC / Android viewer when using E61 module.
If the PIN is enabled, i.e. set to value other than 0000, it needs to be entered
with “Up” / “Down” / “Enter” buttons each time the display wakes up from sleep.
If the PIN is enabled and forgotten it can only be reset via PC / Android viewer
and E61 module.