ME910C1 HW User Guide
1VV0301351 Rev.8 Page 37 of 99 2018-09-28
Figure 1 illustrates a simple circuit to power on the module using an inverted buffer output.
Figure 1: Power-on Circuit
NOTE:
Don't use any pull up resistor on the ON_OFF*/WAKE* line, it is
internally pulled up. Using pull up resistor may bring to latch up
problems on the ME910C1 power regulator and improper power
on/off of the module. The line ON_OFF*/WAKE* must be connected
only in open collector or open drain configuration.
In this document all the lines that are inverted, hence have active low
signals are labelled with a name that ends with”#",”*” or with a bar
over the name.
To check if the device has powered on, the hardware line PWRMON
should be monitored.