ME910C1 HW User Guide
1VV0301351 Rev.8 Page 36 of 99 2018-09-28
5. DIGITAL SECTION
Logic Levels
Power On
To turn on the ME910C1 the pad ON_OFF*/WAKE* must be tied low for at least 5 second
and then released.
The maximum current that can be drained from the ON_OFF*/WAKE* pad is 0,1 mA.
ON_OFF*/WAKE* pad can make an asynchronous wakeup of the system from the PSM
Mode, before the scheduled event of timer T3412 expired.
To make asynchronous exit from PSM mode ON_OFF*/WAKE* pin must be set LOW for at
least 5 seconds.
Parameter Min Max
ABSOLUTE MAXIMUM RATINGS NOT FUNCTIONAL
Input level on any digital pin (CMOS 1.8) with respect to ground -0.3V 2.1V
Operating Range - Interface levels (1.8V CMOS)
Input high level 1.5V 1.9V
Input low level 0V 0.35V
Output high level 1.6V 1.9V
Output low level 0V 0.2V
Parameter
AVG
CURRENT CHARACTERISTICS:
Output Current 1mA
Input Current 1uA

Table of Contents

Other manuals for Telit Wireless Solutions ME910C1 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Telit Wireless Solutions ME910C1 Series and is the answer not in the manual?

Telit Wireless Solutions ME910C1 Series Specifications

General IconGeneral
BrandTelit Wireless Solutions
ModelME910C1 Series
CategoryWireless modules
LanguageEnglish

Related product manuals