83
Verticall
A/D converter
Deflection factor range
(VOLTS/DIV)
Position range
Single bandwidth
8-bit resolution
1 mV/div ~ 20V/div (at input BNC)
± div10
100MHz(72-8710),50MHz(72-8705)
Vo l ta g e d iffe ren ce (Δ V)
m e a s u r e m e n t a c c u r a c y
(average acquisition mode)
When vertical position is zero and N ≥16 :
± ( x reading + div + mV) and mV/div~ mV/div is selected;
± ( x reading + div + mV) and mV/div is selected;
± ( x reading + div + mV) and mV/div~ V/div is selected;
When vertical position is not zero and N ≥16 :
± [ x (reading + vertical shift reading) + ( x vertical shift reading)] + div). Set from
mV/div to mV/div plus mV;
Setup value > 200mV/div to
20V/div plus 50mV.
5% 0.1 1 1 2
4% 0.1 1 5
3% 0.1 1 10 20
3% 1% 0.2
5 200 2
100MHz(72-8710),50MHz(72-8705)
Analog bandwidth
Selectable analog
bandwidth limit (Typical)
20MHz
Low frequency response
(AC coupling, -3dB)
≤ Hz at BNC10
Rise time
3.5ns,7ns at 100MHz and 50MHz bandwidths respectively
DC gain accuracy
When vertical sensitivity is 1mV/div~2mV/div : ± 5% (sample or average acquisition mode);
When vertical sensitivity is 5mV/div : ± 4% (sample or average acquisition mode);
When vertical sensitivity is 10mV/div~
20V/div : ± 3% (sample or average acquisition mode)
DC measurement accuracy
(average acquisition mode)
Under identical setup and environmental conditions, the voltage difference (ΔV) between any two
points of the waveform after the average of ≥16 waveforms acquired waveforms is taken : ± ( x
reading + div)
3%
0.05
DSO Series User Manual