16-pole plug fixed socket pin / wire definitions on bin lift
8
16
7
15
6
14
5
13
4
12
3
11
2
10
1
9
Pin number: Signal type: Signal description: Observation:
1 Input RCV in neutral gear = +24 V 16 to 34 V
2 Not connected Info no bin lift fitted
3 Output Safe distance from footboard level
4 Output Safe distance from footboard level
5 Input Footboards OCCUPIED 0V
6 Output
Clash between bin lift and packer plate
(info to RCV that container is within
reach of packer plate).
+24 V = packer plate stops, as soon as
the container is out of reach of the
packer plate an extra start signal
compaction cycle is given.
7 Bus CleAN open CAN (L)
8 Not connected
9 Not connected
10 Not connected
11 Not connected
12 Input
Emergency stop control system:
normal “safe” state = +24 V
Maximum 3 Amps
13 Output
Signal hopper plate switch (OK = +24 V).
Safety distance okay from ground level.
14 Input
Clash between packer plate and bin lift
(info to bin lift that packer plate is within
reach of container).
+24 V = bin lift stops in horizontal
position out of reach of the packer plate.
15 Bus CleAN open CAN (H)
16 Output
Signal hopper plate switch (OK = +24 V).
Safety distance okay from ground level.
16-pole socket box contact side