11. Replacing counter knife and moving knife
1. Counter knife dismantling:
1) Turn machine off.
2) Release screw [1] and pin [2].
3) Release screw [3] and counter knife [4] (fig. 16).
If the counter knife does not cut thread, it should be replaced.
2. Moving knife dismantling:
1) Lift presser foot using the manual lifter.
2) Release screw [5] and stitch plate [6].
3) Turn pulley and stop needle bar in its highest position.
4) Shift knife mechanism (fig. 17.1) and stop it in a position, where screw [8] is uncovered.
5) Release screw [9] and moving knife.
Attention:
Before releasing the stitch plate and the moving knife, remove the needle.
Installation is carried out in reverse order.