EasyManua.ls Logo

TEXIO PSF-1200L - User Manual

TEXIO PSF-1200L
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
B71-0060-11
INSTRUCTION MANUAL
REGULATED DC POWER SUPPLY
PSF SERIES
PSF-400L
PSF-800L
PSF-1200L
PSF-400L2
PSF-800LS
PSF-1600L

Table of Contents

Questions and Answers

  • W
    William HessAug 16, 2025
    Why is my TEXIO PSF-1200L not turning on?
    • D
      Dr. Melanie Rice MDAug 16, 2025
      If your TEXIO Power Supply isn't turning on, even when the power switch is on, there are a couple of potential reasons. First, the AC power cable might be damaged or not properly connected; check the connection or replace the cable. Second, the input fuse might have blown, which could indicate that the input voltage is outside the allowable range.
  • W
    walkerjermaineAug 19, 2025
    What to do if TEXIO Power Supply output is unstable?
    • J
      Jacob KingAug 19, 2025
      If the output of your TEXIO Power Supply is unstable, it might be oscillating due to the load's influence. Try twisting the load or sensing wires, or change the wire layout. You can also connect a capacitor at the output end of the power source or the load end.
  • A
    Arthur MorrisonAug 22, 2025
    What to do if TEXIO Power Supply displays OHP after starting?
    • S
      Shannon MooreAug 22, 2025
      If your TEXIO Power Supply displays 'OHP' after starting, it means the Overheat Protection (OHP) function is active. You should check the ambient temperature, air intake and exhaust ports, and the dust filter.
  • S
    Sara LevyAug 26, 2025
    Why is OCP displayed when I press the OUTPUT key on my TEXIO PSF-1200L Power Supply?
    • A
      Anthony CampbellAug 26, 2025
      If 'OCP' is displayed when you press the OUTPUT key on your TEXIO Power Supply, it indicates that the Over Current Protection (OCP) value is set too low.
  • E
    Evelyn CampbellAug 28, 2025
    Why is OVP displayed when I press the OUTPUT key on my TEXIO PSF-1200L Power Supply?
    • L
      Lauren MelendezAug 28, 2025
      If 'OVP' is displayed when you press the OUTPUT key on your TEXIO Power Supply, it could be due to a few reasons: * The OVP (Over Voltage Protection) value might be set too low. * The sensing wire(s) might be disconnected. * The resistor might be open in the external resistance control mode.
  • J
    James ChavezAug 31, 2025
    What to do if display disappears quickly on TEXIO PSF-1200L?
    • K
      kbutlerAug 31, 2025
      If the display on your TEXIO Power Supply disappears shortly after starting operation, the fan might be stopping. Check the fan to ensure it is functioning correctly.
  • A
    Anthony PopeSep 3, 2025
    How to fix no output on TEXIO Power Supply?
    • R
      Ryan MirandaSep 3, 2025
      If your TEXIO Power Supply provides no output even when the OUTPUT key is pressed, there are several potential causes: * The set voltage is at '0V'. * The set current is at '0A' (in Constant Current status). * Output On/Off is controlled by external contacts. * The channel output key is not selected, or an incorrect channel is selected. * The keys are locked.
  • K
    Kathryn FrankSep 6, 2025
    Why TEXIO Power Supply current cannot raise to the set value?
    • L
      Laura HamptonSep 6, 2025
      If the current on your TEXIO Power Supply cannot be raised to the set current value, it could be because Constant Power (CP) operation is active, or the CP value is set too low.
  • P
    Patricia WilliamsonSep 9, 2025
    Why won't the output voltage fall on my TEXIO Power Supply?
    • S
      Sarah MullinsSep 9, 2025
      If the output voltage on your TEXIO Power Supply does not fall, it's possible that the Hi-? function is activated.
  • D
    Debra WheelerSep 12, 2025
    What does it mean when TEXIO Power Supply displays '----'?
    • M
      Mark WhiteSep 12, 2025
      If your TEXIO Power Supply displays '----' after starting, it means the unit is specified as a slave unit. Specify the unit as the master unit.

TEXIO PSF-1200L Specifications

General IconGeneral
ModelPSF-1200L
CategoryPower Supply
Output Power1200 W
Input Voltage100-240 VAC
Input Frequency50/60 Hz
Ripple Voltage≤ 10 mVrms
Load Regulation≤ 0.01% + 3mV
Line Regulation≤ 0.01% + 3mV
Display4.3 inch TFT LCD
CoolingForced air cooling
Output Current0 ~ 10A
Ripple & Noise≤ 10 mVrms
InterfaceRS-232, USB
Operating Temperature0 to 40 °C
Storage Temperature-20 to 70 °C
Weight10 kg