Questions and Answers

  • W
    William GarciaSep 9, 2025
    What to do if TEXIO Power Supply output is present momentarily but shuts off quickly and the display indicates “OUP”?
    • D
      daniel64Sep 10, 2025
      If the output is present momentarily but shuts off quickly and the display indicates “OUP”, it may be because the power supply is configured to Remote sense. Check if the positive or negative load wire is loose.
  • M
    Michael SchaeferAug 22, 2025
    Why TEXIO PU6-200 has no output and all displays are blank?
    • B
      Beth ElliottAug 23, 2025
      If your TEXIO Power Supply has no output and all displays are blank, there are a couple of things to check: * First, check the AC power cord for any defects and replace it if necessary. * Second, verify that the AC input voltage is within the specified range and connect to an appropriate voltage source.
  • B
    Benjamin WaltersAug 25, 2025
    Why TEXIO Power Supply output is present momentarily but shuts off quickly and the display indicates “AC”?
    • H
      hknightAug 25, 2025
      If the output of your TEXIO Power Supply appears briefly and then shuts off, with the display showing “AC”, the AC source voltage may be sagging when a load is applied. Check the input AC voltage and ensure it's connected to an appropriate voltage source.
  • P
    Patrick RogersAug 26, 2025
    What to do if TEXIO PU6-200 Power Supply output voltage will not adjust and front panel CV LED is on?
    • R
      Ryan FinleyAug 27, 2025
      If the output voltage of your TEXIO Power Supply won't adjust and the front panel CV LED is lit, it could be that the output voltage is adjusted above the Over Voltage Protection (OVP) setting or below the Under Voltage Limit (UVL) setting. Set the OVP or UVL so they do not limit the output.
  • A
    anthonyallisonAug 27, 2025
    Why TEXIO PU6-200 has large ripple present in output?
    • P
      pinedabryanAug 27, 2025
      If you observe a large ripple in the output of your TEXIO Power Supply, it could be due to the power supply being in remote sense or a high voltage drop on the load wire. Check the load and sense wire connections for noise and impedance effects, and minimize the voltage drop on the load wires.
  • N
    Nicole LopezAug 29, 2025
    Why TEXIO PU6-200 output is present momentarily but shuts off quickly and the display indicates “OUP”?
    • B
      benjamin86Aug 29, 2025
      If the output of your TEXIO Power Supply appears briefly and then shuts off, with the display showing “OUP”, check if the positive or negative load wire is loose.
  • J
    Jeanne WhiteSep 18, 2025
    Why TEXIO PU6-200 Power Supply has poor load regulation and front panel CV LED is on?
    • A
      aallenSep 18, 2025
      If there's poor load regulation and the front panel CV LED is on, it could be due to the sensing wires not being connected properly. Connect the sense wires according to the User’s manual instructions.
  • M
    Mary HoltSep 12, 2025
    How to fix large ripple present in TEXIO PU6-200 output?
    • J
      janice90Sep 12, 2025
      If there's large ripple present in the output, it might be due to the power supply being in remote sense or a high voltage drop on the load wire. Check the load and sense wires connection for noise and impedance effects, and minimize the drop on the load wires.
  • H
    Hannah McdanielSep 8, 2025
    What to do if TEXIO Power Supply output voltage will not adjust and the front panel CV LED is on?
    • S
      smithkevinSep 8, 2025
      If the output voltage will not adjust and the front panel CV LED is on, check if the output voltage is adjusted above the OVP setting or below the UVL setting. Set OVP or UVL so they will not limit the output.
  • J
    Joe RobertsSep 5, 2025
    What to do if TEXIO Power Supply front panel controls are nonfunctional?
    • S
      Scott ReedSep 5, 2025
      If the front panel controls on your TEXIO Power Supply are not working, the power supply might be in Local-Lockout mode. Turn off the AC power and wait until the display turns off. Then, turn on the AC power and press the front panel REM/LOC button.

TEXIO PU6-200 Specifications