    jonfuentesSep 3, 2025
    What to do if TEXIO PU6-200 Power Supply output voltage will not adjust and front panel CC LED is on?
    • K
      kristenhurleySep 3, 2025
      If the output voltage of your TEXIO Power Supply won't adjust and the front panel CC LED is on, the unit is likely in constant current mode. Check the current limit setting and the load current.
  • L
    Logan MurphySep 1, 2025
    How to resolve poor load regulation on TEXIO Power Supply when the front panel CV LED is on?
    • D
      David Buckley MDSep 2, 2025
      If you're experiencing poor load regulation on your TEXIO Power Supply with the front panel CV LED lit, the sensing wires may not be connected properly. Connect the sense wires according to the instructions.
  • B
    brian56Aug 31, 2025
    What to do if TEXIO PU6-200 Power Supply output current will not adjust and front panel CV LED is on?
    • M
      Michael OlsenAug 31, 2025
      If the output current of your TEXIO Power Supply won't adjust and the front panel CV LED is on, the unit might be in constant voltage mode. Check the current limit and voltage setting.
  • N
    Nicole LopezAug 29, 2025
    Why TEXIO PU6-200 output is present momentarily but shuts off quickly and the display indicates “OUP”?
    • B
      benjamin86Aug 29, 2025
      If the output of your TEXIO Power Supply appears briefly and then shuts off, with the display showing “OUP”, check if the positive or negative load wire is loose.
  • A
    anthonyallisonAug 27, 2025
    Why TEXIO PU6-200 has large ripple present in output?
    • P
      pinedabryanAug 27, 2025
      If you observe a large ripple in the output of your TEXIO Power Supply, it could be due to the power supply being in remote sense or a high voltage drop on the load wire. Check the load and sense wire connections for noise and impedance effects, and minimize the voltage drop on the load wires.
  • P
    Patrick RogersAug 26, 2025
    What to do if TEXIO PU6-200 Power Supply output voltage will not adjust and front panel CV LED is on?
    • R
      Ryan FinleyAug 27, 2025
      If the output voltage of your TEXIO Power Supply won't adjust and the front panel CV LED is lit, it could be that the output voltage is adjusted above the Over Voltage Protection (OVP) setting or below the Under Voltage Limit (UVL) setting. Set the OVP or UVL so they do not limit the output.
  • B
    Benjamin WaltersAug 25, 2025
    Why TEXIO Power Supply output is present momentarily but shuts off quickly and the display indicates “AC”?
    • H
      hknightAug 25, 2025
      If the output of your TEXIO Power Supply appears briefly and then shuts off, with the display showing “AC”, the AC source voltage may be sagging when a load is applied. Check the input AC voltage and ensure it's connected to an appropriate voltage source.
  • M
    Michael SchaeferAug 22, 2025
    Why TEXIO PU6-200 has no output and all displays are blank?
    • B
      Beth ElliottAug 23, 2025
      If your TEXIO Power Supply has no output and all displays are blank, there are a couple of things to check: * First, check the AC power cord for any defects and replace it if necessary. * Second, verify that the AC input voltage is within the specified range and connect to an appropriate voltage source.