EasyManuals Logo

Thecus N2800 User Manual

Thecus N2800
163 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
46
S.M.A.R.T. Information
Item
Description
Tray Number
Tray the hard disk is installed in.
Model
Model name of the installed hard disk.
Power ON Hours
Count of hours in power-on state. The raw value of this attribute
shows total count of hours (or minutes, or seconds, depending on
manufacturer) in power-on state.
Temperature Celsius
The current temperature of the hard disk in degrees Celsius.
Reallocated Sector
Count
Count of reallocated sectors. When the hard drive finds a
read/write/verification error, it marks this sector as "reallocated"
and transfers data to a special reserved area (spare area).
This process is also known as remapping and "reallocated"
sectors are called remaps. This is why, on a modern hard disks,
you cannot see "bad blocks" while testing the surface - all bad
blocks are hidden in reallocated sectors. However, the more
sectors that are reallocated, the more a decrease (up to 10% or
more) can be noticed in disk read/write speeds.
Current Pending
Sector
Current count of unstable sectors (waiting for remapping). The
raw value of this attribute indicates the total number of sectors
waiting for remapping. Later, when some of these sectors are
read successfully, the value is decreased. If errors still occur
when reading sectors, the hard drive will try to restore the data,
transfer it to the reserved disk area (spare area), and mark this
sector as remapped. If this attribute value remains at zero, it
indicates that the quality of the corresponding surface area is low.
Test Type
Set short or long time to test.
Test Result
Result of the test.
Test Time
Total time of the test.
Bad Block Scan
NOTE
If the Reallocated Sector Count > 32 or Current Pending Sector of a hard disk
drive > 0 , the status of the disk will show “Warning”. This warning is only used
to alert the system administrator that there are bad sectors on the disk, and
they should replace those disks as soon as possible.

Table of Contents

Other manuals for Thecus N2800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus N2800 and is the answer not in the manual?

Thecus N2800 Specifications

General IconGeneral
BrandThecus
ModelN2800
CategoryServer
LanguageEnglish

Related product manuals