EasyManua.ls Logo

Thermal Dynamics A120 - APPENDIX 3: TORCH PIN - OUT DIAGRAMS; Hand Torch Pin - Out Diagram; Mechanized (Machine) Torch Pin - Out Diagram

Thermal Dynamics A120
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
cutmaster a120
Manual 0-4989 A-3 APPENDIX
APPENDIX 3: TORCH PIN - OUT DIAGRAMS
A. Hand Torch Pin - Out Diagram
1
2
3
4
5
6
7
8
5
6
7
8
1
2
3
4
ATC Female Receptacle
Front View
Pilot
Pilot
6 - Open
7 - Open
8 - Open
5 - Open
Negative /
Plasma
6 - Open
7 - Open
5 - Open
2 - PIP
3 - Switch
4 - Switch
1 - PIP
4 - Green /
Switch
2- Orange /
PIP
3 - White /
Switch
1 - Black /
PIP
Negative /
Plasma
8 - Ground
ATC Male Connector
Front View
A-03701
B. Mechanized (Machine) Torch Pin - Out Diagram
ATC Female Receptacle
Front View
ATC Male Connector
Front View
Negative / Plasma
3 - White -
Pendant
Connector
4- Black -
Pendant
Connector
2 - Orange /
PIP
1 - Black /
PIP
Pilot
2 - PIP
1 - PIP
6 - Open
7 - Open
5 - Open
8 - Ground
8 - Green -
Pendant
Connector
Ground
5 - White /
Not Used
7 - Green /
Not Used
6 - Open
UNSHIELDED MACHINE TORCH
3 - Switch
4 - Switch
Art # A-03799
Negative / Plasma
Pilot
1
2
3
4
5
6
7
8
5
6
8
1
2
3
4
7