Questions and Answers

  • M
    Matthew YoungAug 10, 2025
    What to do if Thermal Dynamics A40i Cutter shows fault and indicators flashing with Error Code E004?
    • A
      Andrea GarrisonAug 10, 2025
      If the fault indicator is flashing and Error Code E004 is displayed, check the following: 1. Ensure the shield cup is hand-tightened until snug. 2. Make sure the torch ATC is securely fastened to the unit. 3. If the problem persists, replace the torch and leads or return to an authorized service center for repair or replacement. 4. If all else fails, return the unit to an authorized service center for repair or replacement, as there may be failed components.
  • J
    Jessica GutierrezAug 15, 2025
    What to do if Thermal Dynamics A40i Cutter shows GAS LED OFF, FAULT and MIN pressure indicators flashing with Error Code E016?
    • D
      David JonesAug 15, 2025
      If the GAS LED is off, and the FAULT and MIN pressure indicators are flashing with Error Code E016, take these steps: 1. Connect the gas supply to the unit. 2. Turn the gas supply ON. 3. Set the air supply inlet pressure to the unit to 120 psi. 4. If the issue continues, return the unit to an authorized service center for repair or replacement due to potential failed components.
  • L
    Linda JonesAug 20, 2025
    What to do if Thermal Dynamics A40i Cutter shows fault indicator flashing with Error Code E002?
    • O
      osinghAug 20, 2025
      If the fault indicator is flashing and Error Code E002 is displayed, the issue may be due to: 1. A primary input voltage problem. Have a qualified person check the primary voltage to ensure it meets the unit requirements. 2. Faulty components in the unit. Return to an authorized service center for repair or replacement.
  • M
    Megan PageAug 26, 2025
    Why Thermal Dynamics Cutter TEMPERATURE indicator is ON, and FAULT indicator is flashing with Error Code E001?
    • K
      kevincoleAug 26, 2025
      If the TEMPERATURE indicator is ON and the FAULT indicator is flashing with Error Code E001, it could be due to: 1. Obstructed air flow through or around the unit. Refer to clearance information. 2. Exceeded duty cycle of the unit. Allow the unit to cool. 3. Failed components in the unit. Return to an authorized service center for repair or replacement.
  • T
    Tyler WhiteAug 29, 2025
    What to do if Thermal Dynamics A40i Cutter shows fault and indicators flashing with Error Code E014?
    • C
      carmenwoodAug 29, 2025
      If the FAULT indicator is flashing and Error Code E014 is displayed, it indicates that the start signal is active when the ON/OFF switch is turned to the ON position. This can occur if: * The hand torch switch is held closed. * The hand pendant switch is held closed. * The CNC START signal is active low. Release the START signal source. If the problem persists, it may be due to a problem in the torch and leads switch circuit, or failed components in the unit. In this case, replace the torch and leads or return to an authorized service center for repair or replacement.
  • M
    molly10Sep 4, 2025
    How to troubleshoot Thermal Dynamics Cutter when ON / OFF Switch is ON but the A/C Indicator does not light?
    • J
      Juan ValenzuelaSep 4, 2025
      If the ON/OFF switch is ON but the A/C indicator does not light, the possible causes and solutions are: 1. The primary power disconnect is in the OFF position. Turn the primary power disconnect switch to the ON position. 2. The primary fuses/breakers are blown or tripped. Have a qualified person check the primary fuses/breakers and connect the unit to a known good primary power receptacle. 3. There are faulty components in the unit. Return it to an authorized service center for repair or replacement.