cutmaster a120
Manual 0-4989 4T-15 OPERATION
Material
Thickness
Gas Pressure
(Air)
Arc Voltage
Torch
Working
Height
Travel Speed
Initial
Piercing
Height
Pierce Delay
Kerf Width
@ Rec.
Speed
(mm)
Bar
(torch lead
length)
Volts (mm) (mm/min) (mm) (sec) (mm)
1.0
4.8 (7.6m)
5.2 (15.2m)
95 4.1 7620 4.1 0.0
1.5
2.0 104 4.1 3500 4.1 0.2
1.6
3.0 115 4.1 2350 4.6 0.3
1.7
4.0 113 4.6 2170 4.6 0.4
1.7
5.0 118 4.6 1740 4.6 0.5
1.8
6.0 125 4.6 1015 4.6 0.8
1.9
8.0 139 4.6 500 Edge Start
2.0
10.0 153 4.6 180 Edge Start
2.2
BOLD TYPE indicates maximum piercing parameters. BOLD ITALIC indicates edge starts only.