Thermann Installer's Manual
Thermann X Split Heat Pump
6
GENERAL
The Thermann X Split Heat Pump must be installed in accordance with the following:
(1) Plumbing Code of Australia.
(2) Installed to meet AS/NZS3500.4 National plumbing and drainage (part 4) code hot
water supply systems – acceptable solutions.
(3) Installed to meet HB 263-2004 Heated water systems plumbing industry commission
(4) Installed to meet AS/NZS 3000 Electrical installations (known as the Australian/New
Zealand wiring rules).
(5) The unit has been specifically designed for domestic hot water heating and is not suit-
able for any other purpose. If installed in a commercial application, then warranties will
be reduced to 1 year for both Tank, Heat pump unit and parts and labour.
(6) The unit is designed to operate when connected to the town water supply with a maxi-
mum operating pressure of 500 kPa. To ensure the mains pressure does not exceed this, a
pressure-limiting device that complies with AS1357 must be connected to the town water
supply line.
(7) This system delivers hot water exceeding 50
0
C. Reference should be made to AS/
NZ3500.4 and/or local regulations relating to the need for temperature tempering devices.
(8) The unit must be stored and transported in an upright position. Failure to do so may
render the unit faulty. Such failure is not covered under any warranty agreements.
INSTALLATION MUST BE CARRIED OUT ONLY BY AN AUTHORISED AND
APPROPRIATELY LICENSED PERSON.
The Thermann X Split Heat Pump is designed to eciently and eectively heat water in
domestic applications. This product is an external CO
2
Heat Pump water heater. These units
are designed to be installed outside and as a kit (tank and heat pump unit).
Thermann X Split Heat Pump units are manufactured to have a factory output of 65
0
C as
standard. Where connected directly to sanitary fixtures used primarily for the purposes of
personal hygiene, it must be fitted with an approved tempering valve into the hot water
piping to any bathroom and/or ensuite.
INTRODUCTION
IMPORTANT NOTE: THIS HOT WATER UNIT IS NOT FOR POOL OR SPA HEATING