Display Explanation Error source
E436 Protect for Freezing Burst Control Error OUTDOOR UNIT
E438 EVI EEV Opening Error OUTDOOR UNIT
E439 Refrigerant Leakage Error (Detect when the system is not operated) OUTDOOR UNIT
E440
1, 4
Heating operation blocked (outdoor temperature over 35°C) OUTDOOR UNIT
E441
1, 4
Cooling operation blocked (outdoor temperature below 9°C) OUTDOOR UNIT
E443 No startup due to Low pressure OUTDOOR UNIT
E458
2
OUTDOOR UNIT fan 1 error OUTDOOR UNIT
E461
2
[Inverter] Compressor startup error OUTDOOR UNIT
E462
2
[Inverter] Total current error/PFC over current error OUTDOOR UNIT
E463
2
OLP is overheated OUTDOOR UNIT
E464
2
[Inverter] IPM over current error OUTDOOR UNIT
E465
2
Compressor V limit error OUTDOOR UNIT
E466
1, 4
DC LINK over/low voltage error OUTDOOR UNIT
E467
2
[Inverter] Compressor rotation error OUTDOOR UNIT
E468
2
[Inverter] Current sensor error OUTDOOR UNIT
E469
2
[Inverter] DC LINK voltage sensor error OUTDOOR UNIT
E470
3
Outdoor unit EEPROM Read/Write error OUTDOOR UNIT
E471
3
Outdoor unit EEPROM Read/Write error (OTP error) OUTDOOR UNIT
E474
1
IPM(IGBT Module) or PFCM temperature sensor error OUTDOOR UNIT
E475
2
OUTDOOR UNIT fan 2 error OUTDOOR UNIT
E483
1, 4
H/W DC_Link over voltage error OUTDOOR UNIT
E484
1, 4
PFC overload error OUTDOOR UNIT
E485
1
Input current sensor error OUTDOOR UNIT
E488
2
AC input voltage sensor error OUTDOOR UNIT
E500
2
IPM is overheated OUTDOOR UNIT
E507 Comp Down due to high pressure or High Pressure Switch Open OUTDOOR UNIT
E554
2
Gas leak error OUTDOOR UNIT
E590
1, 4
Inverter EEPROM CheckSum error OUTDOOR UNIT
E901
1
Water inlet (PHE) temperature sensor error (open/short) OUTDOOR UNIT
E902
1
Water outlet (PHE) temperature sensor error (open/short) OUTDOOR UNIT
E906
1
Refrigerant gas inlet (PHE) temperature sensor (open/short) OUTDOOR UNIT
E911
4
Flow switch OFF Error, this means that several attempts to start has been made before the er-
ror code E911 shows.
▪
In case of flow S/W OFF in 30 sec during water pump signal is ON(Starting)
▪
In case of flow S/W OFF in 15 sec during water pump signal is ON(After starting)
COMM KIT
1) These errors will be automatically cleared, IF there is a COMM KIT active. Further error information can be found in the error log.
2) These errors has to be cleared by restarting the INDOOR UNIT. If the alarm reappears in the display after restarting, it means that the error is still active. Further error information can be found in
the error log.
3) These errors will probably occur due to hardware malfunction on either the COMM KIT or the EEPROM card in the OUTDOOR UNIT. It´s important to know that the EEPROM cards is different
depending on OUTDOOR UNIT size and model. For further support, please contact your installer.
4) These errors will NOT be shown in the INDOOR UNIT display, unless they happen more than 5 times during 120 minutes. Then they must be cleared in the COMM KIT display on the OUTDOOR
UNIT.