35
Date of Origin – 02/24/11
Updated – 02/03/20
Flow Meter Assembly Installation
1. Install Flow Meter Assembly in pressure line at the nose of trailer by pulling collar on female
disconnect back and pushing female disconnect on to male coupler on the nose of the trailer.
Release collar and pull on ow meter assembly to insure the quick disconnects are connected.
2. Connect hydraulic power unit pressure hose to male quick disconnect end of the Flow Meter
Assembly and return hose male quick disconnect to the trailer return line on nose of trailer. Pull
on connections to insure they are connected and secure. Open the needle valve by rotating
CCW before starting the hydraulic power source.