12
Setting Function Parameters Description
FD
Pedestrian Mode
FD-0 No function
FD-1 On (Default setting)
FE
Function Mode
FE-0
Standard Mode(Default
setting)
FE-1 Condominium Mode
FF
Latch release mode
FF-0
Stander gate opening
(Default setting)
FF-1
Release gate tension before
opening(Gate reversing for
0.25s)
FG
Dual / Single gate
FG-1 Single gate
FG-2 Dual gate (Default setting)
FH
Overcurrent Reverses
Time when Close
FH-0 Function OFF (Default setting)
FH-1 0.1 sec
FH-2 0.2 sec
FH-3 0.3 sec
FH-4 0.4 sec
FH-5 0.5 sec
FH-6 0.6 sec
FI
Dkey Terminal Function
FI-0 Function OFF
FI-1
Dual Gate Open/Stop/Close
Stop (Default setting)
FI-2
Single Gate Open/Stop/Close
Stop
FI-3 Pedestrian Mode
FI-4 Open
FI-5 Stop (NO)
FI-6 Stop (NC)
FI-7 Close
FJ
Skey Terminal Function
FJ-0 Function OFF
FJ-1
Dual Gate Open/Stop/Close
Stop
FJ-2
Single Gate Open/Stop/Close
Stop
FJ-3 Pedestrian Mode
FJ-4 Open
FJ-5 Stop (NO) (Default setting)
FJ-6 Stop (NC)
FJ-7 Close
FK
Stop Terminal Function
FK-0 Function OFF
FK-1
Dual Gate Open/Stop/Close
Stop
FK-2
Single Gate Open/Stop/Close
Stop
FK-3 Pedestrian Mode
FK-4 Open
FK-5 Stop (NO) (Default setting)
FK-6 Stop (NC)
FK-7 Close