16
discharge will stop. As shown below:
===================================
Tips:
Please set the Max input voltage to the highest
protection voltage of the power supply. After the voltage
is reached, the charger will automatically stop recycling
discharging. Setting high overvoltage may damage the
input power
===================================
6. End voltage setting (TVC)
Move the cursor to [End Voltage] and press [OK] to
modify the end voltage for the individual cells.
When charging, it is the charge cut-off voltage, and
the range is plus or minus 50mV of the full voltage.
When discharging, it is the discharge cut-off voltage.
Scroll [Scroll wheel] to adjust the value, step 0.01V.