48 W-800
Operation
Menu A:
Set open time
Only in conjunction with function ‘Automatic close’.
1. Select menu item “A”.
After approximately 2 seconds, the display  ashes and shows the set value of the operating mode.
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) buttons.
Menu value Open time (without warning time 10 seconds)
00 s
1 10 s
2 30 s
3 60 s
4 90 s
5 120 s
6 150 s
7 180 s
8 210 s
9 240 s
3. Press the programming button (PROG button)(D).
The value“H” is displayed.
Menu H:
STOP-A settings
1. Select menu item“H”.
After approximately 2seconds, the display  ashes and shows the set value of the operating mode.
The factory setting is“0”.
2. If desired, adjust the setting with the aid of the OPEN(B) and CLOSE(C) buttons.
Value Description Remarks
0 ENS-S8200 or Extra412 (with 8k2resistor) connected to STOP-A input
(terminalG)
1 Jumper or ENS-S1000 connected to STOP-A input (terminalG)
3. Press the programming button (PROG button)(D).
The display shows“0”. End of menu (if necessary, continue with power learning cycle).
Complete the installation procedure
1. Close the cover of the drive head.
2. Check if the garage door operates properly and safely. Refer to the section ‘Maintenance / Checks’.