Instructions for use T-1321 e 9
3 System Overview
T1321_4e
3c 3a 3a
HK
Drive side Opposite drive side
NK NK
5a, 7a
3d
3c
3d
3b 3b
1
4a
4c
8b
7c
7b 6a
6b
2a 4d 4b
8c
7d 7d
2a
8a
2b
1 Drive
Cladding
Motor unit
MCU32 control system with monitoring system, power limitation and perma-
nent diagnosis
Guide system with noise-absorbent guide rail
2 Drive accessories
£ Lock with
a) £ internal manual activation £ in the cladding £ on the wall
b) £ external manual activation
£ Emergency power supply via the battery unit
£ Mechanical emergency opening
3 Door leaves
a) Moving leaves with main closing edge (HK) and secondary closing edge (NK)
b) Moving leaves with floor guide *
c) £ Side part *
d) £ Protection leaves as protection for the secondary closing edge *
4 Operating controls
a) £ iMotion user interface with 6 operating modes and fault display
b) £ Operating mode switch with 3 positions.
c) £ Lock for the user interface
d) £ Remote control of operating modes
5 Activators drive side
a) With automatic activation b) With manual activation
£ Radar with/without direction recognition * £ Push button *
£ IR motion detector * £ Contact-free button *
6 Activators opposite
drive side
a) With automatic activation b) With manual activation
£ Radar with/without direction recognition * £ Key switch
£ IR motion detector * £ Card reader *
£ Remote control *
7 Safety sensors
a) £ Presence sensor *: main closing edge protection
b) £ Presence sensor, external *: main closing edge protection
c) £ Safety beams *
d) £ Presence sensors *: secondary closing edge protection
8 Emergency systems
a) £ Power switch * / fuse *
b) £ Emergency on/off switch *
c) £ Fire alarm system *
9 Output message
£ Bell / gong * £ Light / ventilation * £ Door locked
£ Door status ………………
£ Depending on the system’s equipment.
* Not offered by the manufacturer.
The company installing the system must select and install suitable components in accordance with the prod-
uct standard EN16005 / DIN18650.