Instructions for use T-1321 e 9
3 System Overview
T1321_4e
3c 3a 3a
HK
Drive side Opposite drive side
NK NK
5a, 7a
3d
3c
3d
3b 3b
1
4a
4c
8b
7c
7b 6a
6b
2a 4d 4b
8c
7d 7d
2a
8a
2b
1 Drive
Cladding
Motor unit
MCU32 control system with monitoring system, power limitation and perma-
nent diagnosis
Guide system with noise-absorbent guide rail
2 Drive accessories
£ Lock with
a) £ internal manual activation £ in the cladding £ on the wall
b) £ external manual activation
£ Emergency power supply via the battery unit
£ Mechanical emergency opening
3 Door leaves
a) Moving leaves with main closing edge (HK) and secondary closing edge (NK)
b) Moving leaves with floor guide *
c) £ Side part *
d) £ Protection leaves as protection for the secondary closing edge *
4 Operating controls
a) £ iMotion user interface with 6 operating modes and fault display
b) £ Operating mode switch with 3 positions.
c) £ Lock for the user interface
d) £ Remote control of operating modes
5 Activators drive side
a) With automatic activation b) With manual activation
£ Radar with/without direction recognition * £ Push button *
£ IR motion detector * £ Contact-free button *
6 Activators opposite
drive side
a) With automatic activation b) With manual activation
£ Radar with/without direction recognition * £ Key switch
£ IR motion detector * £ Card reader *
£ Remote control *
7 Safety sensors
a) £ Presence sensor *: main closing edge protection
b) £ Presence sensor, external *: main closing edge protection
c) £ Safety beams *
d) £ Presence sensors *: secondary closing edge protection
8 Emergency systems
a) £ Power switch * / fuse *
b) £ Emergency on/off switch *
c) £ Fire alarm system *
9 Output message
£ Bell / gong * £ Light / ventilation * £ Door locked
£ Door status ………………
£ Depending on the system’s equipment.
* Not offered by the manufacturer.
The company installing the system must select and install suitable components in accordance with the prod-
uct standard EN16005 / DIN18650.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tormax Automatic iMotion 2302 and is the answer not in the manual?

Tormax Automatic iMotion 2302 Specifications

General IconGeneral
BrandTormax Automatic
ModeliMotion 2302
CategoryDoor Opening System
LanguageEnglish

Related product manuals