Thisproductisdesignedtodriveobjectsinto
thegroundwheretheyloseenergyquickly
ingrassareas.However,carelessoperation,
combinedwithterrainangle,ricochets,or
improperlypositionedsafetyguardcanleadto
thrownobjectinjuries.
•Whenapersonorpetappearssuddenlyinor
nearthemowingarea,stopmowing.
•Donotresumemowinguntiltheareais
cleared.
Important:Allowenginetoidlefor5minutes
beforeshuttingitoffafterafullloadoperation.
Thisallowstheturbochargertocooldownbefore
shuttingtheengineoff.Failuretodosomaylead
toturbo-chargertrouble.
Beforestoppingtheengine,disengageallcontrolsand
movethethrottletoSlow .MovingthethrottletoSlow
reduceshighengineRPM,noise,andvibration.Turn
thekeytoOfftostoptheengine.
StandardControlModule
(SCM)
TheStandardControlModuleisa"potted"electronic
deviceproducedina"onesizetsall"conguration.
Themoduleusessolidstateandmechanical
componentstomonitorandcontrolstandardelectrical
featuresrequiredforsafeproductoperation.
Themodulemonitorsinputsincludingneutral,parking
brake,PTO,start,backlap,andhightemperature.The
moduleenergizesoutputsincludingPTO,Starter,and
ETR(energizetorun)solenoid.
Themoduleisdividedintoinputsandoutputs.Inputs
andoutputsareidentiedbygreenLEDindicators
mountedontheprintedcircuitboard.
Thestartcircuitinputisenergizedby12VDC.All
otherinputsareenergizedwhenthecircuitisclosedto
ground.EachinputhasaLEDthatisilluminatedwhen
thespeciccircuitisenergized.UsetheinputLED’s
forswitchandinputcircuittroubleshooting.
Outputcircuitsareenergizedbyanappropriatesetof
inputconditions.ThethreeoutputsincludePTO,ETR,
andSTART.OutputLED’smonitorrelaycondition
indicatingthepresenceofvoltageatoneofthree
specicoutputterminals.
Outputcircuitsdonotdetermineoutputdevice
integritysoelectricaltroubleshootingincludesoutput
LEDinspectionandconventionaldeviceandwire
harnessintegritytesting.Measuredisconnected
componentimpedance,impedancethroughwire
harness(disconnectatSCM),orbytemporarily"test
energizing"thespeciccomponent.
TheSCMdoesnotconnecttoanexternalcomputeror
handhelddevice,cannotbere-programmed,anddoes
notrecordintermittentfaulttroubleshootingdata.
ThedecalontheSCMonlyincludessymbols.Three
LEDoutputsymbolsareshownintheoutputbox.
AllotherLED’sareinputs.Figure19identiesthe
symbols.
Figure19
1.Input5.Inseat
9.Output13.Start
2.Backlap
6.PTOswitch10.PTO
14.Power
3.Hightempshutdown
7.Parkbrakeoff11.Start
4.Hightempwarning8.Neutral12.ETR
HerearethelogicaltroubleshootingstepsfortheSCM
device.
1.Determinetheoutputfaultyouaretryingtoresolve
(PTO,START,orETR).
25