EasyManua.ls Logo

Toro 30856 - Standard Control Module (SCM)

Toro 30856
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Thisproductisdesignedtodriveobjectsinto
thegroundwheretheyloseenergyquickly
ingrassareas.However,carelessoperation,
combinedwithterrainangle,ricochets,or
improperlypositionedsafetyguardcanleadto
thrownobjectinjuries.
Whenapersonorpetappearssuddenlyinor
nearthemowingarea,stopmowing.
Donotresumemowinguntiltheareais
cleared.
Important:Allowenginetoidlefor5minutes
beforeshuttingitoffafterafullloadoperation.
Thisallowstheturbochargertocooldownbefore
shuttingtheengineoff.Failuretodosomaylead
toturbo-chargertrouble.
Beforestoppingtheengine,disengageallcontrolsand
movethethrottletoSlow .MovingthethrottletoSlow
reduceshighengineRPM,noise,andvibration.Turn
thekeytoOfftostoptheengine.
StandardControlModule
(SCM)
TheStandardControlModuleisa"potted"electronic
deviceproducedina"onesizetsall"conguration.
Themoduleusessolidstateandmechanical
componentstomonitorandcontrolstandardelectrical
featuresrequiredforsafeproductoperation.
Themodulemonitorsinputsincludingneutral,parking
brake,PTO,start,backlap,andhightemperature.The
moduleenergizesoutputsincludingPTO,Starter,and
ETR(energizetorun)solenoid.
Themoduleisdividedintoinputsandoutputs.Inputs
andoutputsareidentiedbygreenLEDindicators
mountedontheprintedcircuitboard.
Thestartcircuitinputisenergizedby12VDC.All
otherinputsareenergizedwhenthecircuitisclosedto
ground.EachinputhasaLEDthatisilluminatedwhen
thespeciccircuitisenergized.UsetheinputLED’s
forswitchandinputcircuittroubleshooting.
Outputcircuitsareenergizedbyanappropriatesetof
inputconditions.ThethreeoutputsincludePTO,ETR,
andSTART.OutputLED’smonitorrelaycondition
indicatingthepresenceofvoltageatoneofthree
specicoutputterminals.
Outputcircuitsdonotdetermineoutputdevice
integritysoelectricaltroubleshootingincludesoutput
LEDinspectionandconventionaldeviceandwire
harnessintegritytesting.Measuredisconnected
componentimpedance,impedancethroughwire
harness(disconnectatSCM),orbytemporarily"test
energizing"thespeciccomponent.
TheSCMdoesnotconnecttoanexternalcomputeror
handhelddevice,cannotbere-programmed,anddoes
notrecordintermittentfaulttroubleshootingdata.
ThedecalontheSCMonlyincludessymbols.Three
LEDoutputsymbolsareshownintheoutputbox.
AllotherLED’sareinputs.Figure19identiesthe
symbols.
Figure19
1.Input5.Inseat
9.Output13.Start
2.Backlap
6.PTOswitch10.PTO
14.Power
3.Hightempshutdown
7.Parkbrakeoff11.Start
4.Hightempwarning8.Neutral12.ETR
HerearethelogicaltroubleshootingstepsfortheSCM
device.
1.Determinetheoutputfaultyouaretryingtoresolve
(PTO,START,orETR).
25