•Replaceallpartsincluding,butnotlimitedto,tires,belts,
blades,andfuelsystemcomponentswithoriginalToro
parts.
•Checkthebrakeoperationfrequently.Adjustandservice
thebrakeasrequired.
Model74656
SoundPressure
Thisunithasasoundpressurelevelattheoperator’searof89
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
SoundPower
Thisunithasaguaranteedsoundpowerlevelof100dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
Hand/ArmVibration
Measuredvibrationlevelforrighthand=2.6m/s
2
Measuredvibrationlevelforlefthand=3.2m/s
2
UncertaintyValue(K)=1.6m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
WholeBodyVibration
Measuredvibrationlevel=0.82m/s
2
UncertaintyValue(K)=0.41m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013(RidingandStand-Ons).
Model74660
SoundPressure
Thisunithasasoundpressurelevelattheoperator’searof94
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
SoundPower
Thisunithasaguaranteedsoundpowerlevelof105dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
Hand/ArmVibration
Measuredvibrationlevelforrighthand=2.8m/s
2
Measuredvibrationlevelforlefthand=3.5m/s
2
UncertaintyValue(K)=1.7m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
WholeBodyVibration
Measuredvibrationlevel=0.37m/s
2
UncertaintyValue(K)=0.18m/s
2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013(RidingandStand-Ons).