CoolingSystem
Maintenance
ServicingtheEngineCooling
System
ServiceInterval:Every100hours
Every2years
Removedebrisfromtheoilcoolerandradiatordaily.
Cleanthemmorefrequentlyindirtyconditions.
1.Turntheengineoffandraisethehood.Cleanthe
engineareathoroughlyofalldebris.
2.Removetheknobs(Figure60)securingtheoilcooler
totheframe.
Figure60
1.Knobs
3.Pivottheoilcoolerrearward.Cleanbothsidesofthe
oilcoolerandradiatorarea(Figure61)thoroughly
withcompressedair.Startfromthefrontandblow
thedebrisouttowardstheback.Thencleanfrom
thebacksideandblowtowardsthefront.Repeat
procedureseveraltimesuntilallchaffanddebrisis
removed
Important:Cleaningtheradiatororoilcooler
withwatercanpromoteprematurecorrosion
anddamagetocomponents.
Figure61
1.Oilcooler
2.Radiator
4.Pivottheoilcoolerbackintoposition.Secureitto
theframewiththeknobsandclosethehood.