1.Pressthe[Boom1Cal]key.
2.Pressthe[Enter]key.
3.Enter80(USorTU)or204(SI).
4.Pressthe[Enter]key.
5.Pressthe[Boom2Cal]key.
6.Pressthe[Enter]key.
7.Enter60(USorTU)or152(SI).
8.Pressthe[Enter]key.
9.Pressthe[Boom3Cal]key.
10.Pressthe[Enter]key.
11.Enter80(USorTU)or204(SI).
12.Pressthe[Enter]key.
EnteringtheSpeedCalNumber
TheSpeedCalnumberiscriticaltotheperformance
ofthespraysystem.Ensurethatthetiresareproperly
inatedandthatthetankishalffullbeforeperforming
thisprocedure.
1.Pressthe[SpeedCal]key.
2.Pressthe[Enter]key.
3.EnterthecorrectSpeedCalnumberforyourcurrent
selectedunitofmeasurement(US,SI,TU).
WhenusingUSunits,enter:148.
WhenusingSIunits,enter:38.
WhenusingTUunits,enter:148.
4.Pressthe[Enter]key.
Note:Thesenumberallowthemachinetooperate
withreasonableaccuracy.Finetuningisnecessary
formaximumaccuracy.
Fine-tuningtheSpeedCalNumber
Thefollowingprocedurerequiresbuttons1through
8tohavebeenpopulatedwithdataandtheCALto
stopashing.Usethefollowingproceduretofurther
ne-tunetheSpeedCalnumber:
1.Measure500feet(152m)onaatgroundsurface.
2.Setthedistancereadoutto0.
3.Pressthe[Distance]key.
4.Pressthe[Enter]key.
5.Enter0.
6.Pressthe[Enter]key.
7.Drivethevehicle500feet(152m).
8.Ensurethatthedistancereadoutontheconsole
computerreadsbetween490feetand510feet(149
mand155m).
9.Ifthereadoutisnotbetween490feetand510feet
(149mand155m),calibratetheSpeedCalusing
thefollowingequation:
NewSpeedCalnumber=148x500/Distance
readout(forUSorTUunits)
NewSpeedCalnumber=38x152/Distance
readout(forSIunits)
10.EnterthenewSpeedCalnumberusingtheEntering
theSpeedCalNumberprocedure.
EnteringtheValveCalNumber
TheValveCalnumbercontrolstheresponseofthespray
systemtomeetthechangesofthevehiclespeed.
Important:Runningthecontrolvalvetoofast(a
numbergreaterthanzero)willcausethesystemto
oscillate.
ToentertheValveCalnumber:
1.Pressthe[ValveCal]key.
2.Pressthe[Enter]key.
3.EntertheValveCalcalibrationnumber.
Note:TheinitialvalvecalibrationnumberforValve
Calis023.Werecommendthatyouusethisnumber
formostsprayapplications;046maybehelpful
forsmallapplicationrates(0.4gallons/min.or1.5
liters/min.).
4.Pressthe[Enter]key.
EnteringOptionalCalibrationValues
Youmayalsowanttoenterthefollowingdata,butitis
notrequiredforoperatingthespraysystem.
VolumeTank
Thisnumberrepresentsthevolumeofmaterialinthe
tankandmustbeenteredeachtimeyourellthetank.
Thefunctionmonitorsthetankvolumewhileyouare
sprayingbasedonthetotalamountapplied.
1.Pressthe[Vol/Tank]key.
2.Pressthe[Enter]key.
3.Entertheamountofmaterialinthetank.
4.Pressthe[Enter]key.
Time
Enterthetimeofdaybasedona24-hourday.For
example,1:30p.m.is13:30.Youcanalsoenter0to
measureelapsedtime.
Tosetthedate,dothefollowing:
1.Pressthe[Time]key.ThedisplayshowsMONTH.
2.Pressthe[Enter]keytochangethemonth.
15