EasyManuals Logo

Toro Pro Control XP User Manual

Toro Pro Control XP
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Problem
PossibleCauseCorrectiveAction
1.Youincorrectlyenteredanumberinthe
consolecomputer.
1.Verifythatallthenumbersenteredin
theconsolecomputerarecorrect.
2.Thewheeldrivesettingisnotsetto
SP3.
2.SetthewheeldrivesettingtoSP3.
3.TheSpeedCalnumberisincorrect.3.EnterthecorrectSpeedCalnumber.
4.TheRate1orRate2displayisnot
constantwhenthespeedisconstant.
4.Ensurethattheowmeterispointing
inthedirectionofowandthenozzles
areappropriatefortheratesetting.
5.Thepressurecannotbeadjustedin
manualmodewiththeagitationonand
theboomsoffinthehighendofthe
pressurerange.
5.Verifythatthereisvoltageatthe
valveconnectorbyplacingtheMaster
switchtoManwiththeboomsinthe
Offpositionandthepowerswitchto
theOnposition.Manuallyoperatethe
Incr/Decrswitchtoverifythevoltage.
6.TheValveCalnumberisnotproperly
set.
6.EnterpropertheValveCalnumber.
Therateisinaccurateorunstable
7.Thereisaproblemwiththeprocessor
boardassembly.
7.HaveanAuthorizedDistributorreplace
theprocessorboardassembly.
1.Therearebreaksinthecableleading
tothehydrauliccontrolvalve.
1.Replacethecable.
2.Theconnectionsinthecablelineare
dirty.
2.Cleanorreplacethecableline.
3.Thereisnovoltageatthevalve
connector.
3.Verifythatthereisvoltageatthevalve
connectorbyplacingtheMasterswitch
totheManpositionwiththeboomsin
theOffpositionandthepowerswitchto
theOnposition.Manuallyoperatethe
Incr/Decrswitchtoverifythevoltage.
Youcannotvarytherateinmanualor
automaticmode
4.TheRateInc/Decswitchisfaulty.4.ReplacetheRateInc/Decswitch.
1.Therearebreaksorshortsinthe
owmetercable.
1.T esttheowmetercableandrepairor
replaceitifnecessary.RefertoT esting
theFlowmeterCableonpage15.
2.Theinsideoftheowmeterisdirtyor
notproperlyadjusted.
2.Cleanandmakeanynecessary
adjustmentsinsidetheowmeter.
Thetotalvolumedoesnotregister
3.Theowmetertransducerisnot
operatingproperly.
3.Replacetheowmetertransducer.
1.Theowmeterisnotpointinginthe
directionoftheow.
1.Installtheowmeterinthedirectionof
theow.
Thetotalvolumeregistersowinaccurately
2.Theowmeterisfaulty.2.T esttheowmetercableandrepairor
replaceitifnecessary.RefertoT esting
theFlowmeterCable.
18