Starting Problems (continued)
Condition Possible Cause Correction
Engine cranks, but does not start Injection pump ETR solenoid wir- Clean and tighten or repair as
(if
engine cranks, cause of prob- ing loose or corroded. necessary.
le
m is not in interlock system).
Injection pump ETR solenoid faulty. Test solenoid. Replace if faulty.
Glow relay faulty. Test glow relay. Replace if faulty.
Glow relay/glow plug wiring loose, Check wiring and connections.
c
orroded or damaged. Clean, tighten or repair as neces-
sa
ry.
Glow plugs faulty. Test glow plugs and replace if
faulty.
Engine or fuel system problem. See Troubleshooting section of
Chapter 3 - Engine.
Engine cranks (but should not) Traction switch out of adjustment Adjust or replace traction switch.
wit
h traction pedal out of neutral. or faulty.
Engine cranks (but should not) PTO switch faulty. Replace PTO switch.
wit
h PTO switch ON.