31
When the TMC-424E is shipped from the factory, or the control module has been restored to
factory default settings, the following control parameters are selected:
NOTE: The program default settings, indicated by an asterisk (*), are restored by the Erase feature
provided within Special Functions.
Factory Default Abbreviation
Current Time – 12:00 a.m.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . n/a
Month January. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . JAN
Year – 2008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . n/a
Day – 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . n/a
*Station Times All Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . n/a
*Start Times All Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . n/a
*Calendar Days All On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . n/a
*Odd/Even Days All Off (no excluded days). . . . . . . . . . . . . . . . . . . . . . . . . . . . n/a
*Interval Days All Off (no excluded days). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INT
*Season Adjust 100% (program and month) . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 %
*Station Delay No (All Off) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SD - -
*Master Valve Operation by Program – Yes (All on) . . . . . . . . . . . . . . . . . . . . . . . MV[A] -Y
Master Valve Exclusion by Station No (No stations excluded) . . . . . . . . . . . . . . MVS - N
*Pump Delay No (All Off) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PD - -
*Pump Enable No (All Off during station delay) . . . . . . . . . . . . . . . . . . . . . . . . . PE - N
*Cycle Repeats/Delays No (All Off) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CYC - N
Simultaneous Programs – 1 (stacked) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1PROG
Handheld Remote Operation – Yes (On). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HH -Y
Display Language – English. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ENG
Clock Time Format – 12-hour (a.m./p.m). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12H
Seconds Time Increments – No (Off). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SEC - N
Timed Bypass – No (Off) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TBP - N
*Rain Sensor/Program Yes (All On) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS[A] - Y
*Main Line Fill (delay) 0 Minutes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FIL:0M
Master Valve (type) – NC (Normally Closed). . . . . . . . . . . . . . . . . . . . . . . . . . . . . MV:NC
Nominal Flow – All Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NF - -
Assign Station to Flow Sensor No (All Off) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FLO - N
Overflow – All Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OF - -
Underflow – All Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UF - -
Critical Flow – All Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CF - -
Learned Flow – All Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LF - -
Rain Delay – Off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
Appendix D: Default Settings - Abbreviations