Figure49
1.Oillter
3.Adapter
2.Gasket
FuelSystem
Maintenance
ServicingtheFuelFilter
DrainingtheWaterSeparator
ServiceInterval:Every40hours
1.Positionthemachineonalevelsurface.
2.DisengagethePTO,movethemotioncontrollevers
totheneutrallockedpositionandsettheparking
brake.
3.Stoptheengine,removethekey,andwaitforall
movingpartstostopbeforeleavingtheoperating
position.
4.Locatethewaterseparatoratthebackleftofthe
machine.
5.Placeadrainpanbelowthewaterseparator.
6.Openthedrainvalveonthewaterseparator
approximatelyoneturntoallowwaterandother
contaminatestodrain(
Figure50).
7.Closethedrainvalvewhenonlydieselfuelcomes
out(
Figure50).
Figure50
1.Drainvalve
3.Backofmachine
2.Waterseparator
39