430 Series
Procedure 4 Connector Check
The Display unit has an LCD module, FL, Display switch, and FL inverter board. The FL
and FL inverter board are connected by two cables. The LCD module and VGA board are
connected as shown below. Any of these cables may be disconnected.
Disassemble the display unit and check the following cable connections. Refer to Chapter 4,
Replacement Procedures, for more information about how to disassemble the computer.
Figure 2-3 430CDS display connection
Figure 2-4 430CDT display connection
Firmly reconnect any cable which has become disconnected, then repeat Procedures 1 and 2.
If the problem still exists, perform Procedure 5.