6
© 2007 - 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO167/207/237
SCANNER
6 - 27
[J] CIS unit drive belt-2
(3) Take off the CIS unit drive belt-1.
Note:
When assembling the CIS unit drive belt-1,
assemble it while the fixing screw is loos-
ened. Then tighten the fixing screw of the
tension bracket.
Fig. 6-38
(1) Take off the scanner top cover.
P.6-18 "[B] Scanner top cover"
(2) Take off the right rear cover.
P.2-22 "[I] Right rear cover"
(3) Take off the CIS unit drive belt-1.
P.6-26 "[I] CIS unit drive belt-1"
(4) Loosen 2 fixing screws of the scan motor.
Fig. 6-39
(5) Take off the CIS unit drive belt-2.
Note:
When assembling the CIS unit drive belt-2,
be sure to perform the tension adjustment for
the scan motor.
P.6-20 "[D] Scan motor (M1)"
Fig. 6-40
CIS unit drive belt-1
Scan motor
CIS unit drive belt-2