© 2007 - 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO167/207/237
DEVELOPMENT SYSTEM
12 - 15
(4) Remove 2 plate springs fixing the doctor
sleeve on its both ends.
Fig. 12-16
(5) Remove 2 screws on both ends of the doctor
sleeve and remove 2 coil springs.
Note:
When the screws on both ends of the doctor
sleeve are removed, be sure to adjust the
doctor sleeve gap (0.45±0.05 mm) after
assembling.
(Refer to Service Handbook Chap.3.8)
Fig. 12-17
(6) Remove 1 screw and take off the polarity
adjustment lever.
Note:
Make a note of the position where the polar-
ity adjustment lever is pointing. (Mark the
position if needed.) When reassembling,
match the polarity adjustment lever with the
previously marked position on the scale.
Fig. 12-18
Plate spring
Plate spring
Screw
Screw
Coil spring Coil spring
Polarity adjustment lever