13
© 2007 - 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO167/207/237
FUSER / EXIT UNIT
13 - 15
(4) Close the guide, and then take off the guide
by sliding its rear hinge to the right side.
Fig. 13-15
(5) Remove 1 spring and take off the guide while
the guide is being slid to the rear side.
Fig. 13-16
(6) Remove the Mylar.
(7) Disconnect 1 connector, release 2 latches,
and then take off the exit sensor.
Fig. 13-17
1
2
Guide
Spring
Exit sensor
Connector
Mylar