e-STUDIO350/450 SCANNER 6 - 2 November 2003 © TOSHIBA TEC
6
6.2 Construction
a. Exposure lamp
This lamp is the light source to irradiate the original on the glass. (One 16W xenon lamp)
b. Lamp inverter
Controls lighting of the xenon lamp.
c. Reflector
This is a plate to efficiently direct the light from the exposure lamp to the surface of the original on
the glass.
d. Mirror-1
This mirror directs the light reflected from the original to the mirror-2 described later.
Fig. 6-202
Fig. 6-201
The following shows the construction and purpose of the scanning system:
(1) Original glass
This is a glass on which original is placed. The light from the exposure lamp is irradiated to the
original through this glass.
(2) Carriage-1
Carriage-1 consists of the exposure lamp, lamp inverters, reflector, mirror-1, etc. It is driven by the
scan motor and scans an original on the glass.
Reflector
Lamp inverter
Exposure lamp
Mirror-1
Original glass
Original
Exposure lamp
Lamp inverter
Reflector
Mirror-1

Table of Contents