November 2003 © TOSHIBA TEC 12 - 7 e-STUDIO350/450 DEVELOPMENT SYSTEM
12
12.4.3 Adjustment using the temperature / humidity sensor
Variation in the output (V
ATS
) of the auto-toner sensor due to humidity is corrected using the temperature
/ humidity sensor to maintain the toner density in the developer material at a certain amount.
12.4.4 Adjustment using the drum thermistor
Variation in the output (V
ATS
) of the auto-toner sensor due to temperature is corrected using the drum
thermistor to maintain the toner density in the developer material at a certain amount.
Feedback control by drum thermistor in setting mode (08)
Item to be controlled
Toner output control by drum thermistor
Code
08-840
Default
ON