e-STUDIO350/450 FUSER UNIT / PAPER EXIT SECTION 13 - 6 November 2003 © TOSHIBA TEC
13
CN No.
CN455-1
CN455-2
CN455-3
CN455-4
CN455-5
CN455-6
CN455-7
CN455-8
CN456-1
CN456-2
CN456-3
CN456-4
CN456-5
Name of signal
IH2 ON
VDD
H1PWR1
H1PWR2
H1PWR3
H2PWR1
H2PWR2
H2PWR3
IH1 ON
SG
NC
H1ERR1
H1ERR2
Direction
LGC to IH
LGC to IH
-
IH to LGC
Definition
IH coil energization permitting signal
Switching signal of power setting
IH coil energization permitting signal
Not connected
IH status signal (*Note)
13.4.3 IH control circuit interface
The IH control circuit uses a photocoupler as an insulation against the secondary circuit.
The interface signals are as follows.
(*Note) IH status signal
When the temperature (due to insufficient cooling) of the switching element (IGBT) is abnormal:
“10: Coil is abnormal, IH FAN OFF” After a certain period of time Error [C480]
When the upper limit of the power voltage is abnormal: “00: Initializing” After a certain period
of time Error [C470]
When the lower limit of the power voltage is abnormal: “00: Initializing” After a certain period
of time Error [C470]
Defective circuits : “11: Abnormal circuit, IH coil abnormality” Error [C490]
Ready state after the initialization: “01: Ready”