November 2003 © TOSHIBA TEC 2 - 19 e-STUDIO350/450 OUTLINE OF THE MACHINE
2
Function
Exposing the original to the light
Removing the residual charge from
the drum surface
Heating the fuser roller
Preventing condensation of the
mirrors of the carriages
*ASD/AUD/CND/SAD/TWD models:
Standard
*NAD/MJD models: Option
Preventing condensation of the lens
*ASD/AUD/CND/SAD/TWD models:
Standard
*NAD/MJD models: Option
Preventing condensation of the drum
*ASD/AUD/CND/SAD/TWD models:
Standard
*NAD/MJD models: Option
Name
LP-EXPO
Exposure lamp
LP-ERS
Discharge LED
IH-COIL
IH coil
SCN-L-DH
Scanner damp heater (Left)
SCN-R-DH
Scanner damp heater (Right)
DRM-DH
Drum damp heater
Symbol
EXP
ERS
IH-COIL
DH1
DH2
DH3
P-I
P21 - I6
P25 - I33
P31 - I23
P10 - I22
P10 - I32
P27 - I7
Remarks
B-1
D-2
J
B-2
B-2
D-2
(6) Lamps and heaters
(7) Thermistors and thermostats
Name
THMS-C-HTR
Main thermistor
THMS-S-HTR
Edge thermistor
THMS-DRM
Drum thermistor
THERMO-FSR
Fuser thermostat
THERMO-SCN-DH
Scanner damp heater thermostat
THERMO-DRM-DH
Drum damp heater thermostat
Symbol
THM1
THM2
THM3
THMO1
THMO2
THMO3
Function
Detecting the surface temperature at
the center part of the fuser roller
Detecting the surface temperature at
the edge of the fuser roller
Detecting the temperature at the drum
surface
Preventing overheating in the fuser
unit
Controlling the temperature of the
scanner damp heater
Controlling the temperature of the
drum damp heater
P-I
P29 - I10
P29 - I10
P26 - I29
P29 - I9
P10 - I22
Remarks
J
J
D-2
J
B-2
D-2
P27 - I7

Table of Contents