170 ACE-tronics G9 ASD Installation and Operation Manual
Acc/Dec Pattern 1
Program Special Accel/Decel 1 – 4
This parameter enables a user-selected preprogrammed output profile that
controls the acceleration and deceleration pattern for the #1 Accel/Decel
profile.
Settings:
Linear
S-Pattern 1
S-Pattern 2
The figures below provide a profile of the available accel/decel patterns.
Direct Access Number F502
Parameter Type — Selection List
Factory Default Linear
Changeable During RunYes
Linear acceleration and deceleration is the default
pattern and is used on most applications.
S-Pattern 1 is used for applications that require
quick acceleration and deceleration. This setting is
also popular for applications that require shock
absorption at the start of acceleration or
deceleration.
S-Pattern 2 decreases the rate of change above
the base frequency for acceleration and
deceleration.
F502 F502
efesotomasyon.com -Toshiba inverter,drive,servo,plc

Table of Contents