219
11 Transformer 10)Remove the transformer housing back
screws and then remove the housing.
(M4 x 0.2' (6mm), 4 pcs)
11)Remove the screws that secure the base
plate and transformer, and then replace
the transformer.
(M6 x 0.47' (12mm), 4 pcs)
2. Re-assembly procedure
Perform the disassembly procedure in
reverse to re-assemble.
(11)1)).
Note:
1)When performing wiring inside the
transformer housing, make sure that 4.7
inches (120 mm) of the black tube covered
part of the leads extend from the holder.
2)When bundling the leads, make sure that
the distance between the band and the
bend is 2.6 inches (65 mm), as shown in the
figure.
No. Part to be replaced Work procedure Remarks
Screw tightening locations for transformer housing back
Right side
Left side
Transformer
housing
10) Screws
Back
Screw tightening locations for transformer re-assembly
Two screws each,
front and back
Base plate
Holder
4.7'
2.6'
Provide 2.6 inches between
bottom and lead bend.