8
12
OTHERSOTHERS
Gas Leak Test
• Check the fl are nut connections 
for the gas leak with a gas leak 
detector or soap water.
   Stripping length of the connecting cable
Model RAS-13N3KV Series
Power source 50Hz, 220 – 240 V Single phase
Maximum running current 9.1A
Circuit breaker 12.0A
Power cord H07RN-F or 60245 IEC66 (1.5 mm
2
 or more)
Connecting cable H07RN-F or 60245 IEC66 (1.5 mm
2
 or more)
CAUTION
Connecting cable Power cord
Earth lineEarth line
Connecting 
cable
Terminal 
block
Power 
cord
•  Wrong wiring connection may cause some electrical parts burn out.
•  Be sure to comply with local cords on running the wire from indoor unit 
to outdoor unit (size of wire and wiring method, etc.).
•  Every wire must be connected fi rmly.
•  This installation circuit breaker must be used specifi ed for the power 
supply line of this air conditioner.
•  If incorrect or incomplete wiring is carried out, it will cause an ignition or 
smoke.
•  Prepare the power supply for exclusive use with the air conditioner.
•  This product can be connected to the mains.
 Connection to fi xed wiring: A switch which disconnects all poles and 
has a contact separation of at least 3 mm must be incorporated in the 
fi xed wiring.
To separate using of remote control for each indoor unit in case of 2 air 
conditioner are installed near.
Remote Control B Setup.
1.  Press [RESET] button on the indoor unit to turn the air conditioner ON.
2.  Point the remote control at the indoor unit.
3.  Push and hold [CHECK] button on the Remote Control by the tip of the 
pencil. “00” will be shown on the display (Picture 1).
4.  Press [MODE] during pushing [CHECK]. “B” will show on the display 
and “00” will disappear and the air conditioner will turn OFF. The Remote 
Control B is memorized (Picture 2).
Remote Control A-B Selection
•  When two indoor units are installed in the same room or adjacent two 
rooms, if operating a unit, two units may receive the remote control signal 
simultaneously and operate. In this case, the operation can be preserved 
by setting either one remote control to B setting. (Both are set to A setting 
in factory shipment.)
•  The remote control signal is not received when the settings of indoor unit 
and remote control are different.
•  There is no relation between A setting/B setting and A room/B room when 
connecting the piping and cables.
Test Operation
To switch to the TEST RUN (COOL) 
mode, press [RESET] button for 
10 seconds. (The beeper will make 
a short beep.)
Auto Restart Setting
The product was shipped with Auto Restart function in the off position. 
Turn it on as required.
This product is designed so that, after a power failure, it can restart automatically 
in the same operating mode as before the power failure.
Information
RESET button
    How to set the Auto Restart
1.  Press and hold the [RESET] button on the indoor unit for 3 seconds to set 
the operation (3 beep sound and OPERATION lamp blink 5 time/sec for 
5 seconds).
2.  Press and hold the [RESET] button on the indoor unit for 3 seconds to 
cancel the operation (3 beep sound but OPERATION lamp does not 
blink).
  •  In case of ON timer or OFF timer are set, AUTO RESTART OPERATION 
does not activate.
/
1
/
1
30 30
40 40
10
10
10
10
Wiring Connection
1.  Remove the valve cover from the outdoor unit.
2.  Connect power cord to the terminal block L, N and 
 then connect 
the connecting cable to the terminals as identifi ed with their respective 
matched numbers on the terminal block of indoor and outdoor unit.
3.  Insulate the unused cords (conductors) from any water coming in the 
outdoor unit. Proceed them so that they do not touch any electrical or 
metal parts.
Note :  1.  Repeat above step to reset Remote Control to be A.
    2.  Remote Control A have not “A” display.
    3.  Default setting of Remote Control from factory is A.
Check places for
the indoor unit.
Check places for
the outdoor unit.