4
  NOTE
•  Use stranded wire only.
•  Wire type : More than H07RN-F or 60245 IEC66 (1.5 mm
2
 or more)
1.  Open the air inlet grille upward.
2.  Securely remove two screws at the front panel.
3.  Slightly open the lower part of the front panel then pull the upper part of 
the front panel toward you to remove it from the rear plate as shown on 
fi gure 1.
4.  After removing the front panel, remove the Display unit and open the 
cover as shown on fi gure 2 and 3.
5.  Arrange the control wire as detail and specifi cation as shown on fi gure 
4.
6.  Securely connect the control wire to terminal of Display unit board as 
shown on fi gure 5 (tighten fi rmly but not over 0.12 N·m (0.01 kgf·m)).
7.  Set the control wire throughout at slot on front cover of Display unit then 
reassembly Display with main casing by reverse process of fi gure 2 and 
3. Make sure the control wire must not be pressed by front and rear 
cover of Display unit.
8.  Set the control wire out from indoor unit same portion as power supply 
and connecting cable as shown on fi gure 6.
9.  Reassembly the indoor unit by reverse process of 1 to 3.
Indoor unit
Control wire
Remote controller
How to Connect Remote Controller 
for Wire Operation
     For indoor unit
Air inlet grille
Front panel
Display board
1
23
Display unit
  1. Remove cover of remote controller by sliding down and take it out.
  2. If batteries are exist, please take them out. The combination of using 
wire controller and batteries may cause of batteries explosion.
  3. Make hole for insert control wire by use screwdriver break the polyester 
sheet as shown on fi gure 7.
  4. Insert control wire from rear side of remote controller as shown on 
fi gure 8.
  5. Fix control wire which arrange as shown on fi gure 9 and ! to terminal 
by provided screws (tighten fi rmly but not over 0.25 N·m (0.03 kgf·m)).
  6. Set control wire through gutter way at rear side of remote controller as 
shown on fi gure ".
  7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as 
shown on fi gure #.
  8. Mark and arrange hole for fi x below screw (Ø3.1×25L) as shown on 
fi gure #.
  9. Assembly battery cover which provided with accessory bag then use 
provide screw (Ø3.1×25L) to fi x battery cover together with wall as 
shown on fi gure $ (tighten fi rmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
     For remote controller
* Wire size 28-22AWG 
or 0.08-0.32 mm
2
  Outer diameter not over 4.7 mm, 
control wire length less than 30 m.
70 mm
5 mm
4
65
Terminal
Control wire
Notch for wire out
Control wire
Tighten fi rmly but 
not over 0.12 N.m 
(0.01 kgf.m)
78
Polyester sheet
close hole for 
insert control wire
Control wire
Control wire
Hole for hang
remote controller
Remote controller
Control wire
Screw (Ø3.1×16L) 
for hang remote 
controller
Wall
Screw (Ø3.1×25L) 
for fi x battery cover
Remote controller
9
"
!
#
Control wire
Terminal
* Wire size 28-22AWG 
or 0.08-0.32 mm
2
  Outer diameter not over 4.7 mm, 
control wire length less than 30 m.
30 mm
10 mm
Tighten fi rmly but 
not over 0.25 N.m 
(0.03 kgf.m)
3
Stripping length of the connecting cable
Screw
Terminal 
cover
Cord 
clamp
Terminal block
Earth line
Screw
100 mm
10 mm
10 mm
90 mm
Connecting cable
about 20 cm
01_1115551106-EN.indd   401_1115551106-EN.indd   4 6/19/2557 BE   2:25 PM6/19/2557 BE   2:25 PM