EasyManua.ls Logo

Toshiba RAS-B10J2FVG-E - Operation Description 1. Basic Operation; Operation Control

Toshiba RAS-B10J2FVG-E
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item
1. Basic
operation
Operation flow and applicable data, etc.
1. Operation control
Description
Receiving the users operation condition setup, the operation statuses of indoor/outdoor units are
controlled.
1) The operation conditions are selected by the remote controller or indoor unit display buttons as
shown in the bolow.
2) A signal is sent by ON button of the remote controller.
3) The signal is received by a sensor of the indoor unit and processed by the indoor controllers as
shown in the below.
4) The indoor controller controls the indoor fan motor and louver motor.
5) The indoor controller sends the operation command to the outdoor controller, and sends/receives
the control status with a serial signal.
6) The outdoor controller controls the operation as shown in the left, and also controls the compres-
sor, outdoor fan motor, 4-way valve and pulse Modulating valve.
Indoor unit
Indoor unit control
Command signal generating function of
indoor unit operation
Calculation function (temperature calculation)
Activation compensation function of indoor fan
Cold draft preventive function
Timer function
Indoor heat exchanger release control
Indoor fan motor
Louver motor
Outdoor unit
Outdoor unit control
Frequency control of inverter output
Waveform composite function
Calculation function
(Temperature calculation)
AD conversion function
Quick heating function
Delay function of compressor reactivation
Current release function
IPM over-current preventive function
Defrost operation function
Compressor
Outdoor fan motor
4-way valve
Pulse Modulating valve
(P.M.V.)
Signal receiving
Indoor unit control
Operation command
Serial signal send/receive
Serial signal send/receive
Outdoor unit control
Inverter
~
Remote controller
Control contents of remote controller
ECO
ON timer setup
OFF timer setup
Hi-POWER
Fireplace
8°C
Selection of
operation conditions
ON/OFF
ON/OFF
Operation select
(AUTO/COOL/DRY/HEAT/FAN ONLY)
Temperature setup
Air direction
Swing
Air volume select
(
AUTO/LOW/LOW+/MED/MED+/HIGH/QUIET
)
COMFORT SLEEP
POWER-SEL
PRESET
SILENT
FLOOR
WEEKLY TIMER
Selecton
of
operation
conditions
Control contents of
unit display buttons
ON/OFF
Operation select
(AUTO/COOL/HEAT/
FAN ONLY)
Temperature setup
Air outlet select
(AUTO/Upper/Lower
Indoor unit display buttons