1. Basic
operation
Operation flow and applicable data, etc.
Description
Item
4. DRY operation
DRY operation is performed according to the
difference between room temperature and the setup
temperature as shown below.
In DRY operation, fan speed is controlled in order to
prevent lowering of the room temperature.
1) Detects the room temperature (TA) when
the DRY operation started.
2) Starts operation under conditions in the
left figure according to the temperature
difference between the room tempera-
ture and the setup temperature (Tsc).
Setup temperature (Tsc)
= Set temperature on remote controller
(Ts) + (-1.0 to 0.0)
3) When the room temperature is lower
2°C or less than the setup temperature,
turn off the compressor.
4) The time correction is performed every
8 minutes.
Fan Time
TA speed correction
(°C)
12 35 37 49 W8
11 32 34 42 W6
10 30 31 36
927 28 30
825 26 24
722 23 18
620 20 11
5 W5
4 W4
3
2
1
−1 zone
OFF OFF OFF (min 1)
+1 zone
±0
0
Compressor speed (rps)
B10J2FVG-E
B13J2FVG-E B18J2FVG-E
Zone
+4.5
+4.0
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
0.0
−1.0
−1.5
−2.0
−0.5