Item
Operation flow and applicable data,etc
Description
27. Fireplace
Operation
Fireplace button on remote controller is pressed.
Fireplace 1:
Cancel cold draft prevention control and fan
speed depend on user require base on basic
control.
Fireplace 2:
Cold draft prevention control is active with super
low fan speed (640 rpm).
Keep air circulation during other heat
source applied.
Note:
With Fireplace operation on heating
mode indoor unit always runs and cold
air breezing might be occurred.
Fireplace Operation
28. 8C heating /
Frost
protective
operation
8C Button on remote controller is pressed.
Set temperature is performed for 5C to 13C
and no cold draft prevention control.
Intended for cold latitudes and
performs objective heating operation.
8C heating operation
8°C
Normal
operation
8°C
Normal
operation
Fireplace#1
Fireplace#2
Fireplace#1
Fireplace#2