EasyManua.ls Logo

Toshiba RAS-B10J2FVG-E - Operation Characteristic Curves; Capacity Variation According to Temperature

Toshiba RAS-B10J2FVG-E
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-2. Operation Characteristic Curve.
<Cooling>
<Heating>
2-3. Capacity Variation ratio According to Temperature.
<Cooling> <Heating>
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30 40 50 60 70 80 90 100 110
CURRENT (A)
COMPRESSOR SPEED (RPS)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
0
1
2
3
4
5
6
7
8
9
10
0 10 20 30 40 50 60 70 80 90 100 110
CURRENT (A)
COMPRESSOR SPEED (RPS)
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 5m
Pipe Length : 7.5m(18k Only)
Voltage : 230V / 50Hz
RAS-B13J2FVG-E
RAS-B10J2FVG-E
RAS-B18J2FVG-E
RAS-B18J2FVG-E
RAS-B13J2FVG-E
RAS-B10J2FVG-E
Pipe Length : 5m
Pipe Length : 7.5m (18k Only)
Voltage : 230V / 50Hz
50
55
60
65
70
75
80
85
90
95
100
105
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Outside Temperature (
o
C)
CCoooolilinngg CCaappaaccitityy rraattio io ((%%))
Capacity ratio : 100 %=
2.50kW(RAS-B10J2FVG-E)
3.50kW(RAS-B13J2FVG-E)
5.00kW(RAS-B18J2FVG-E)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 5m
Pipe Length : 7.5m (18k Only)
0
20
40
60
80
100
120
-15 -10 5 10
Heating Capacity ratio (%)
-5 0
Outside Temperature (ºC)
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 5m
Pipe Length : 7.5m (18k Only)
Voltage : 230V / 50Hz
Capacity ratio : 100 %=
3.20kW(RAS-B10J2FVG-E)
4.20kW(RAS-B13J2FVG-E)
6.00kW(RAS-B18J2FVG-E)
RAS-B18J2FVG-E
- 8 -
Voltage : 230V / 50Hz

Table of Contents