10-5-3. Remote Control A-B Selection
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Push and hold CHECK button on the Remote Control by the tip of the pencil.
2. Press . "B" will show on the display and "00" will during pushing CHECK
disappear and the air conditioner will turn OFF. The Remote Control B
is memorized
Note : 1. Repeat previous step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
Unit B setup.
Press and hold MODE button for more than 20 seconds.
When A setup changed to B setup : 5 beeps will sound and operation
lamp blinks for 5 seconds.
When B setup changed to A setup : 5 beep will sound.
10-5-5. Auto Restart Setting
How to turn ON the Auto Restart Function
Press and hold the [OPERATION] button on the indoor
unit for 3 seconds (3 beep sounds and OPERATION lamp
blink 5 time/sec for 5 seconds).
This product is designed so that, after a power failure, it can
restart automatically in the same operating mode as before
the power failure.
10-5-4. Test Operation
To switch the TEST RUN (COOL) mode, press OPERATION button for 10
seconds (The beeper will make a short beep).
Information
The product are shipped with Auto Restart function in
the OFF position. Turn it ON as required.
"00" will be shown on the display
(Picture 1
).
(Picture 2).
How to turn OFF the Auto Restart Function
Press and hold the [OPERATION] button on the indoor
unit for 3 seconds (3 beep sounds but OPERATION lamp
does not blink).
NOTE :
In case of NO timer or OFF timer are set, AUTO
RESTART OPERATION does not activate.