– 19 –
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
RAS-10SKH-E-1
RAS-13SKH-E
– 19 –
Specifications
DC 35V, 19W
10kΩ at 25°C
DC390V, Secondary DC35V, 12V, 7V
Coil : DC12V 75mA, Rated AC250V 20A
10kΩ at 25°C
10mH, AC 0,6A
4A, 600V
100µF, 450V
T3,15A, 250V
Coil DC12V, 33mA, Rated 1A 250V AC
4A, 600V
560V
5,6 Ω, 5W
Output (Rated) 2W, 10 poles, 1 phase DC 12V
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Type
ICF-35-19-3
or
TICF-35-19-3
(microprocessor)
SWT-34
TMP87CK40F
DI1U
(microprocessor)
RF-103YOR6
RBV-406
CEAUF2W101M20
MT3
AJQ1341
MA2830-FJ
15G561K
ERF-5TK5R6
CT422920S-01
MP35EA7
Parts name
Fan motor (for indoor)
Thermo. sensor
(TA-sensor)
DC-DC transformer (T01)
Microcomputer
Power relay (RY01),
Common relay (RY02)
Heat exchanger sensor
(TC-sensor)
Line filter (L01)
Diode (DB01)
Capacitor (C02)
Fuse (F01)
Relay (for outdoor fan motor,
solenoid coil) (RY03, RY04)
Power supply IC (IC01)
Varistor (R21, R109)
Resistor (R01)
Current trans (T02)
Louver motor