– 20 –
No. Parts name Type
1 Compressor PH170T2-4L2
2 Fan motor (for outdoor) AF-230-28P
3
Running capacitor
SK-50FMP
(for fan motor)
4
Running capacitor
SK-40CMP35U1
(for compressor)
5
Solenoid coil
LB60012
(for 4-way valve)
6 Overload relay J-MRA99257-9200
7 Thermostat for Compressor CS-7
6-2. Outdoor Unit
RAS-3M31SAH-E-1 (Upper Unit)
Specifications
Output (Rated) 1100W, 2 pole, 1 phase, 220/230/240V, 50Hz
Winding resistance ()
Red-Black White-Black
(at 20°C)
2,22 3,04
Output (Rated) 28W, 6 pole, 1 phase, 220/230/240V, 50Hz
Winding resistance ()
Red-Black White-Black
(at 20°C)
198 160
500V AC, 1,5µF
400V AC, 35µF
AC : 200/240V
UT 8,0A (80°C), OPEN 145±5°C, CLOSE 75±11°C
130°C OFF, 70°C ON
No. Parts name Type
1 Compressor PH120T1-4C
2 Fan motor (for outdoor) AF-230-28P
3
Running capacitor
SK-45FMP
(for fan motor)
4
Running capacitor
SK-40CMP30U1
(for compressor)
5
Solenoid coil
LB60012
(for 4-way valve)
6 Overload relay J-MRA99269-9200
7 Transformer FT-70
8 Outdoor P.C. board MCC-738
9
Heat exchanger sensor
(microprocessor)
(TE-sensor)
Specifications
Output (Rated) 750W, 2 pole, 1 phase, 220/230/240V, 50Hz
Winding resistance ()
Red-Black White-Black
(at 20°C)
4,53 8,73
Output (Rated) 28W, 6 pole, 1 phase, 220/230/240V, 50Hz
Winding resistance ()
Red-Black White-Black
(at 20°C)
198 160
450V AC, 2µF
400V AC, 30µF
AC : 200/240V
U/T 6,8A (90°C), OPEN 135±5°C, CLOSE 69±11°C
AC : 220/240V
10k at 25°C
RAS-M18SAH-E
RAS-3M31SAH-E-1 (Lower Unit)
RAS-4M36SAH-E (Upper and Lower Unit)